พร้อมส่ง

ICO240 Standard Delivery CO₂ Incubator

SKU : SKU44589
The ICO240 CO₂ Incubator is the ultimate solution for laboratories that require maximum capacity, precision, and reliability in cell culture and research environments. As the largest model in the ICO series, it offers a 240-liter chamber volume, engineered to maintain exceptional temperature uniformity, humidity stability, and contamination control — even under intensive use.

รายละเอียดสินค้า

ICO240 Standard Delivery CO Incubator

Extra-Large CO Incubator for High-Volume and Critical Laboratory Applications
The ICO240 CO Incubator is the ultimate solution for laboratories that require maximum capacity, precision, and reliability in cell culture and research environments.
As the largest model in the ICO series, it offers a 240-liter chamber volume, engineered to maintain exceptional temperature uniformity, humidity stability, and contamination control even under intensive use.
Built with German precision engineering, the ICO240 delivers outstanding performance for high-demand applications such as biotechnology, pharmaceuticals, and industrial microbiology.

Specification 

Temperature
Working-temperature range
5 °C above ambient temperature up to +50 °C
Standard sterilisation programme: 60 minutes at 180°C (without removing the sensors)
Setting temperature range
+18 to +50 °C
Setting accuracy temperature
0.1 °C
Temperature sensor
2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error
Temperature variation in chamber
at + 37 °C +/- 0.3 K
Temperature fluctuations with time
at 37 °C +

Humidity
Humidity control (standard)
Humidity limitation thanks to a Peltier element; when water dish is full and inserted, the Peltier element limits the value of relative humidity in the interior to 93 % rh +/- 2.5 %
Setting accuracy humidity
0.5 % rh
Setting range active humidity control (with option K7)
40 to 97 % rh and rh-Off

Control of standard components
CO2 control
Digital electronic CO2 control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation
Adjustment range CO2
0 to 20 % CO2
Setting accuracy CO2
0,1%
Variation in time CO2
+/- 0.2 % CO2
Adjustment range O2
1 to 20 % O2
Setting accuracy O2
0.1 % O2